Product Description: Our company has researched, developed, and manufactured the S11-M series fully sealed oil-immersed power transformers, which feature low losses, low noise, and high efficiency, delivering significant energy savings and reducing environmental pollution. Compared with conventional oil-immersed transformers, the fully sealed design eliminates the conservator tank; instead, the elastic corrugated fins of the corrugated tank automatically accommodate and compensate for changes in oil volume. This complete isolation from ambient air effectively prevents and slows down oil degradation and insulation aging, enhancing operational reliability and enabling maintenance-free operation under normal conditions.
Product Features:
1. The transformer core is assembled from high-quality, imported cold-rolled silicon steel laminations, which significantly reduces no-load losses and no-load current. In addition, the core is securely braced to ensure tight packing and minimize noise.
2. Both the high- and low-voltage windings are wound with oxygen-free copper. For low-voltage windings of 500 kVA and below, a double-layer cylindrical structure is used; for those of 630 kVA and above, a double-helix or quad-helix structure is employed. The high-voltage winding adopts a multi-layer cylindrical structure.
3. The transformer connection group is configured as Dyn11 to reduce the impact of harmonics on the power grid and improve power quality.
4. The transformer features a fully sealed design, which extends its service life and eliminates the need for core lifting and routine maintenance.
5. The measured noise level is below the standard.
After normal transportation, transformers in this series can be installed with the relevant components and subjected to acceptance tests without the need for core-extraction inspection; upon passing these tests, they may be put into operation.
Terms of Use:
1. Maximum ambient temperature: +40°C
2. Minimum ambient temperature: -25°C
3. Altitude: <1000m
4. Maximum monthly average relative humidity: 90% (20°C)
5. Installation Location: The equipment shall be installed in indoor or outdoor locations that are free from fire hazards, explosion risks, severe contamination, chemical corrosion, and significant vibration.
Implementation Standard:
GB 1094.1 Power Transformers
GB/T 15164 Load Guidelines for Oil-Immersed Power Transformers
GB/T 6451 Technical Parameters and Requirements for Three-Phase Oil-Immersed Power Transformers
GB 2536 Transformer Oil
JB/T 3837 Method for Coding Transformer Product Models
JB/T 501 Test Guidelines for Power Transformers
GB 1094.3 Insulation Levels and Insulation Tests for Power Transformers—Air Gaps in External Insulation
DU T572 Transformer Operating Procedures