24

2022-01

Isolation devices shall be installed at the interface between low-voltage control cabinets and electrical cabinets.

Derive reasonable measurement methods for the no-load loss and load loss of a transformer.

24

2022-01

Control cabinet manufacturers should prevent the inadvertent closing of circuit breakers and load switches.

Prevent the operation of isolating switches under load. (Isolating switches shall not be operated when circuit breakers, load switches, or contactors are closed.)

24

2022-01

Condensation may occur in high-voltage variable-frequency drives when the ambient temperature changes.

Control cabinets are used in both indoor and outdoor applications for power and lighting distribution as well as motor control, and are suitable for wall-mounted installation indoors or floor-mounted installation outdoors.

05

2022-01

A Low-Voltage Automatic Continuous Adjustable Filtering Reactive Power Compensation Device [Utility Model Patent]

This utility model discloses a low-voltage, automatically and continuously adjustable filter-type reactive power compensation device that falls within the scope of grid reactive power compensation equipment. The device employs a tunable reactor composed of a single-phase capacitor in series with an inductor, as well as a current-limiting reactor formed by a series-connected limiting inductor ahead of the capacitor, as its compensation elements. These elements are respectively connected to switching elements J1–J4, a no-load controller, a PLC programmable controller, and a power-factor transmitter. A thyristor-based voltage regulator adjusts the tunable reactor according to commands from the PLC programmable controller, thereby achieving automatic control of the power factor within the range of 0.95 to 0.99. This utility model features harmonic suppression, making it suitable for applications with high harmonic levels and large inrush currents. The device centers on a PLC-controlled circuit to ensure stable power-factor operation. By utilizing composite switches as the switching devices for the capacitor banks, it ensures that the grid consistently maintains a high power factor, reduces line losses, and improves power quality.

05

2022-01

The Role of Reactive Power Compensation with Capacitors and Reactors

1. Suppressing inrush current during switching: As we know from circuit theory, the voltage across a capacitor is 0 V before it is charged, and the voltage across a capacitor cannot change abruptly. Therefore, at the instant of switching-in, a capacitor is theoretically equivalent to a short circuit. If the capacitor is switched in when the grid voltage is not crossing zero, a large inrush current will occur, imposing significant stress on both the power grid and the switching devices. In contrast, an reactor (i.e., an... 2. It has the function of suppressing harmonics at a certain frequency. When a capacitor is connected in series with a reactor, they form an LC series circuit, which has a specific natural frequency given by f = 1/(2π√(LC)). When the external frequency equals this natural frequency, the LC circuit theoretically exhibits zero impedance.

05

2022-01

Tendering scale has increased substantially, and 2022 is expected to see strong growth.

In the first three quarters of 2021, wind-turbine equipment tender volumes totaled 41.9 GW, up 115% year on year. Assuming that the scale of public-market tenders in the fourth quarter of 2021 does not decline sharply, we project that full-year public-market tender volumes for 2021 will be around 60 GW. Based on tender volumes in 2020 and 2021, we estimate that new installed capacity in 2021 and 2022 will be approximately 40 GW and 55 GW, respectively, with 2022 seeing year-on-year growth of more than 30% in new wind-power installations.